How to Solve KESS V2 V2.13 firmware V4.036 Wake up error

Problem:

When trying to read Bosch ECU EDC17 with KESS V2 v2.13 firmware 4.036 ECU tuning kit, the software prompted “Wake up error”

Possible reason:

1)TF connection issue

Kess V2 fails to read out TF card program or the program in the TF card not working properly

2)Select wrong ECU type.

Select wrong ECU type will cause wake up error either.

Solution:

KESS TF card communication failure 2 common occasions:

1) The four pins of chip on the PCB board are not soldered firmly

2) The chip is loosed or has been used long time
KESS V2 V2.13 firmware V4.036 Wake up error

Please follow the correct way to fix

1. Solder the chip one more to make it tightly connected to the PCB main board

2. Clean up the shrapnel on the card slot with a brush

3. If the card slot shrapnel is not flexible enough, lift up the shrapnel a little bit to make sure it can communicate well with the TF card

4. Clean the TF card and then put it back to card slot.

If the kess v2 “wake up error” still exits, format the TF card then copy the software to TF card.

1. Format TF card

2. Contact customer service to send you the software in the TF card

3. Unzip the file, copy and paste all 4 files to the TF card
KESS V2 V2.13 firmware V4.036 Wake up error
KESS V2 V2.13 firmware V4.036 Wake up error
(Do not directly copy the zip rar. file to the TF card, do not create a new folder in TF card and copy and unzip it)
KESS V2 V2.13 firmware V4.036 Wake up error
If the two above methods do not work, re-flash the CPU program, and then copy and paste the software to the TF card again.

The “Wake up error” solution fits KESS V2 V2.10
http://www.obdii365.com/wholesale/best-price-kess-v2-tuning-kit.html