Ford SID206 is similar architecture ecu as SID208. KT200 ecu programmer can read them fine via both OBD and BDM mode.
1.SID206
OBD Mode:
obd okay read, write. Ford kuga 2.0tdci 136km sid206 Read and write obd okey. Checksum not checked, counted winols
BDM Mode
SID206 BDM read and write successfully (in 18 minutes)
KT200 SID206 BDM boot mode pinouts
Kit to use:
Multifunction cable
Siemens/Marelli adapter
Grey flat cable
Connectors dip/sip
Connect multifunction cable as follows:
Insert Siemens/Marelli adapter as in photo:
2. SID208
OBD Mode
Ford transit custom continental sid 208 obd read write checksum by obd works 100%.
NOTE: You can write safe BDM read via OBD! You cant write OBD read by BDM – bdm is full read – OBD only calibrations
BDM Mode
SIEMENS CONTINENTAL SID208 [ TC1797 INT.F.] – Ford
Step 1: READ AND WRITE ECU
Connect with the multifunction cable the following
pinout and the boot shown below
Use the driver:
→ TOOLS BOOT MODE
→ INFINEON TRICORE Boot
→ SAK TC1797
KT200 SID208 BDM boot pinout
Step 2: PASSWORD SEARCH
Disable boot mode by removing all connections on the pcb.
Connect the pinout below (red wire +12V instead of green ignition).
Use the driver:
→ TOOLS BOOT MODE
→ INFINEON TRICORE Tool Password
→ OBD PASSWORD SID208 FORD – LAND ROVER
→ Click on “Find Password” and follow the software messages.
Attention: If you cannot find the password from pinuot, you must launch the driver in OBD on the vehicle.
NOTE: Now that the password has been found it’s possible to read and write the control unit as described above in STEP 1.